Diseño · Madera

Resistencia de diseño a compresión axial de pilar de madera en incendio (EN 1995-1-2)

  • Tipo: Resistencia
  • Versión 1
  • revisado el 21/11/2026

Resistencia de diseño a compresión axial de un pilar de madera en incendio incluyendo el coeficiente de pandeo según EN 1995-1-2 cláusula 4.2.2: NcRdfi = kcfi · Aef · fc0dfi.

Nc,Rd,fi=kc,fi⋅Aef⋅fc,0,d,fi\displaystyle N_{\mathrm{c},\mathrm{Rd},fi} = k_{\mathrm{c},fi} \cdot A_{\mathrm{ef}} \cdot f_{\mathrm{c},0,\mathrm{d},fi}
  • EN 1995-1-2:2004
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

kcfiNcRdfi

Formula and quantities

SymbolNameUnitNote
kcfi\displaystyle k_{cfi}Coeficiente de pandeo para la sección residual en incendio1
Aef\displaystyle A_{\mathrm{ef}}Área residual eficaz de la sección transversalmm²
fc0dfi\displaystyle f_{c0dfi}Resistencia de diseño a compresión paralela a la fibra en incendioN/m²
NcRdfi\displaystyle N_{cRdfi}Resistencia de diseño a compresión axial en incendiokNResult

Ejemplo resuelto

kcfi\displaystyle k_{cfi} = 0,65 1 · Aef\displaystyle A_{\mathrm{ef}} = 20.164 mm² · fc0dfi\displaystyle f_{c0dfi} = 27.600.000 N/m²

NcRdfi\displaystyle N_{cRdfi} = 361,74 kN

Standard and source

Standard
EN 1995-1-2:2004
Result
NcRdfi\displaystyle N_{cRdfi} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
NcRdfi\displaystyle N_{cRdfi} = 361,742 kN= (0,65 1) · (20.164 mm²) · (27.600.000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

La búsqueda comienza en Diseño › Madera.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.