设计 · 木结构

木柱火灾下轴向受压设计承载力 (EN 1995-1-2)

  • 类型:承载力
  • 版本1
  • 2026/11/21已审核

根据 EN 1995-1-2 第 4.2.2 条计入屈曲折减系数的火灾下木柱轴向受压设计承载力:NcRdfi = kcfi · Aef · fc0dfi。

Nc,Rd,fi=kc,fi⋅Aef⋅fc,0,d,fi\displaystyle N_{\mathrm{c},\mathrm{Rd},fi} = k_{\mathrm{c},fi} \cdot A_{\mathrm{ef}} \cdot f_{\mathrm{c},0,\mathrm{d},fi}
  • EN 1995-1-2:2004
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

kcfiNcRdfi

Formula and quantities

SymbolNameUnitNote
kcfi\displaystyle k_{cfi}火灾下剩余截面的屈曲折减系数1
Aef\displaystyle A_{\mathrm{ef}}有效剩余截面面积mm²
fc0dfi\displaystyle f_{c0dfi}火灾下顺纹抗压设计强度N/m²
NcRdfi\displaystyle N_{cRdfi}火灾下轴向受压设计承载力kNResult

实例

kcfi\displaystyle k_{cfi} = 0.65 1 · Aef\displaystyle A_{\mathrm{ef}} = 20,164 mm² · fc0dfi\displaystyle f_{c0dfi} = 27,600,000 N/m²

NcRdfi\displaystyle N_{cRdfi} = 361.74 kN

Standard and source

Standard
EN 1995-1-2:2004
Result
NcRdfi\displaystyle N_{cRdfi} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
NcRdfi\displaystyle N_{cRdfi} = 361.742 kN= (0.65 1) · (20,164 mm²) · (27,600,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

检索将在 设计 › 木结构 开始。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.