設計 · 木構造

木造柱の火災時設計軸圧縮耐力 (EN 1995-1-2)

  • タイプ:耐力
  • バージョン1
  • 2026/11/21にレビュー済み

EN 1995-1-2 第4.2.2項による座屈低減係数を含む火災時木造柱の設計軸圧縮耐力: NcRdfi = kcfi · Aef · fc0dfi.

Nc,Rd,fi=kc,fi⋅Aef⋅fc,0,d,fi\displaystyle N_{\mathrm{c},\mathrm{Rd},fi} = k_{\mathrm{c},fi} \cdot A_{\mathrm{ef}} \cdot f_{\mathrm{c},0,\mathrm{d},fi}
  • EN 1995-1-2:2004
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

kcfiNcRdfi

Formula and quantities

SymbolNameUnitNote
kcfi\displaystyle k_{cfi}火災時残存断面の座屈低減係数1
Aef\displaystyle A_{\mathrm{ef}}有効残存断面積mm²
fc0dfi\displaystyle f_{c0dfi}火災時繊維方向設計圧縮強度N/m²
NcRdfi\displaystyle N_{cRdfi}火災時設計軸圧縮耐力kNResult

例題

kcfi\displaystyle k_{cfi} = 0.65 1 · Aef\displaystyle A_{\mathrm{ef}} = 20,164 mm² · fc0dfi\displaystyle f_{c0dfi} = 27,600,000 N/m²

NcRdfi\displaystyle N_{cRdfi} = 361.74 kN

Standard and source

Standard
EN 1995-1-2:2004
Result
NcRdfi\displaystyle N_{cRdfi} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
NcRdfi\displaystyle N_{cRdfi} = 361.742 kN= (0.65 1) · (20,164 mm²) · (27,600,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 木構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.