Design · Timber

Fire design axial compression resistance of timber column (EN 1995-1-2)

  • Type: Resistance
  • Version 1
  • reviewed on 11/21/2026

Design axial compression resistance of a timber column in fire including buckling reduction factor according to EN 1995-1-2 Clause 4.2.2: NcRdfi = kcfi · Aef · fc0dfi.

Nc,Rd,fi=kc,fi⋅Aef⋅fc,0,d,fi\displaystyle N_{\mathrm{c},\mathrm{Rd},fi} = k_{\mathrm{c},fi} \cdot A_{\mathrm{ef}} \cdot f_{\mathrm{c},0,\mathrm{d},fi}
  • EN 1995-1-2:2004
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

kcfiNcRdfi

Formula and quantities

SymbolNameUnitNote
kcfi\displaystyle k_{cfi}Buckling reduction factor for residual section in fire1
Aef\displaystyle A_{\mathrm{ef}}Effective residual cross-sectional areamm²
fc0dfi\displaystyle f_{c0dfi}Design compressive strength parallel to grain in fireN/m²
NcRdfi\displaystyle N_{cRdfi}Design axial compression resistance in firekNResult

Worked example

kcfi\displaystyle k_{cfi} = 0.65 1 · Aef\displaystyle A_{\mathrm{ef}} = 20,164 mm² · fc0dfi\displaystyle f_{c0dfi} = 27,600,000 N/m²

NcRdfi\displaystyle N_{cRdfi} = 361.74 kN

Standard and source

Standard
EN 1995-1-2:2004
Result
NcRdfi\displaystyle N_{cRdfi} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
NcRdfi\displaystyle N_{cRdfi} = 361.742 kN= (0.65 1) · (20,164 mm²) · (27,600,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Timber.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.